Double-conversion Online UPS 6000VA / 5400W, 12V / 7AH*16 with Fully Digital LCD Display ,RS232, 230VAC, 50/60Hz – Built-in input power factor corrector, avoids reactive power loss, saving user energy
Double-conversion Online UPS 6000VA 5400W
Double-conversion Online UPS 6000VA 5400W
Performance, Professional Power UPS, guaranteeing full protection of terminal equipment, operating in reliable On-line technology.
On-line technology provides full separation of terminal equipment from the power supply. The power supply is also a generating unit. From the mains through a rectifier or in case of a power failure from an installed battery, an independent inverter supplies the output voltage in the form of a perfect wave without frequency fluctuations. Online UPS means the highest quality of output current. Line voltage spikes, discharges, surges are not dangerous to the final consumer devices.
Features
Applications
Front Panel
Rear Panel
Model | AP-PX6K |
Power | 6000VA/5400W |
INPUT | |
---|---|
Voltage | HV: 208/220/230/240VAC LV: 100/110/120/127VAC |
Voltage range | HV: 90-300VAC ±5VAC LV: 60-145VAC ±3VAC |
Frequency | 50/60Hz |
Frequency range | 40-70Hz ±0.5Hz |
Power Factor | > 0.99 |
Input Bypass voltage range AC | HV: 115-285VAC ±1-3% LV: 80-140VAC ±1-3% |
BATTERY | |
---|---|
Nominal voltage | 144V |
Type and capacity | 12V / 7Ah x 12 |
Hold time | 50% load ? 8 minutes 100% load ? 3 minutes |
Charging time | 5 hours to 90% |
OUTPUT | |
---|---|
Nominal voltage | HV: 208/220/230/240VAC ±2% LV: 100/110/120/127VAC ±2% |
Output waveform | Pure sine wave THD < 3% (linear load) THD < 7% (non linear load) |
Frequency | 60/50Hz ±1-4Hz |
Dynamic output voltage | <9% |
Dynamic transient recovery | <100ms |
Output overload | 105-125% ? 60s 126-150% ? 30s |
Peak power factor | 3:1 |
Switching time | 0ms |
Information | The operating times shown are approximate and may change depending on operating conditions, environment, operating time and more. |
CONNECTIVITY | |
---|---|
Service ports | RS232 USB type B (cable included) |
OS support | Windows/macOS/Linux |
PROTECTION | |
---|---|
Type | Input or output voltage above or below range Overload Over temperature Short circuit protection |
ENVIRONMENTAL CONDITIONS | |
---|---|
Humidity | 0-90% / Relative Humidity 0-40°C (non-condensing) |
Noise level | Lower than 50dB |
Dimensions (mm) | 380 x 325 x 190 |
Net Weight (kg) | 20.5 |
Front Panel | On/Off Switch Function Button |
Rear panel | 1 x Input to screw terminals (L/N+PE) 1 x Output to screw terminals (L/N+PE) Service port RS232 and USB type B (cable included) 2 x Fuse (inputs C32 and outputs C63) 2 x Fan |
498 $
Out of stock
Out of stock
Double-conversion Online UPS 6000VA / 5400W, 12V / 7AH*16 with Fully Digital LCD Display ,RS232, 230VAC, 50/60Hz – Built-in input power factor corrector, avoids reactive power loss, saving user energy
Double-conversion Online UPS 6000VA 5400W
No account yet?